node-red-contrib-cip-suite

Comprehensive Node-RED nodes for Allen-Bradley and CIP-capable devices via EtherNet/IP. Covers the full spectrum from modern ControlLogix to legacy SLC500/PLC-5, plus advanced CIP objects for motion, energy, time sync, security, and more.

Supported Hardware

Platform Protocol Notes
ControlLogix (L6x, L7x, L8x) CIP Symbolic Slot-based backplane routing
CompactLogix (L1x, L2x, L3x) CIP Symbolic Typically slot 0
Micro800 (Micro820/850/870) CIP Symbolic No backplane — enable Micro800 mode
SLC 500 PCCC over CIP File-based addressing (N7:0, F8:0)
MicroLogix (1100/1400) PCCC over CIP File-based addressing
PLC-5 PCCC over CIP File-based addressing
Third-party CIP devices CIP Raw Any EtherNet/IP device with CIP objects

Installation

cd ~/.node-red
npm install node-red-contrib-cip-suite

Or search for node-red-contrib-cip-suite in the Node-RED Palette Manager.

Node Overview

All nodes appear under the CIP Suite category with a grey CIP icon.

Core CIP Nodes
Node Type Description
cip-endpoint Config Shared TCP session to a Logix PLC. Auto-reconnect, Micro800 support, multi-hop routing.
cip-read In/Out Read tag values. Supports bit access (Tag.5), array elements (Tag[3]), array ranges (Tag[0..9]), UDT/structures, batch reads, and polling.
cip-write In/Out Write tag values. Supports bit-level writes (atomic via CIP 0x4E or software RMW), arrays, UDT partial merge, batch writes.
cip-browse In/Out Discover tags on the PLC. Glob/regex filtering, UDT detection, program-scoped tags.
cip-subscribe Out Continuous cyclic multi-tag scanning via readTagGroup(). Deadband filtering, report-by-exception, runtime reconfiguration.
cip-controller In/Out Read controller identity, mode, fault status, keyswitch, tag count. Runtime commands: run/program/test/reset.
cip-raw In/Out Send raw CIP service requests. Supports Multiple Service Packet (0x0A). Full response parsing with human-readable status codes.
cip-discover In/Out UDP broadcast ListIdentity for network device discovery. Standalone — no endpoint required.
Legacy PCCC Nodes (SLC500 / MicroLogix / PLC-5)
Node Type Description
cip-pccc-endpoint Config Raw TCP session with EtherNet/IP + PCCC encapsulation. Transaction-based request/response matching.
cip-pccc-read In/Out Read PCCC addresses: N7:0, F8:0, B3:0/5, T4:0.ACC, S:1/5. Multi-element reads, polling.
cip-pccc-write In/Out Write PCCC addresses with bit-level read-modify-write support.
Advanced CIP Object Nodes
Node CIP Class Description
cip-io-scanner Class 1 Implicit I/O via ForwardOpen + UDP. Cyclic data exchange with remote I/O, drives, servos.
cip-security 0x5D CIP Security Object — TLS/DTLS status and security profile reading.
cip-sync 0x43 IEEE 1588 PTP time synchronization — grandmaster discovery, offset monitoring, PTP enable/disable.
cip-motion 0x42 Motion Axis Object — jog, moveAbsolute/Relative, home, stop, enable/disable, gear ratio, axis status polling.
cip-energy 0x4F/0x4E Energy Object — power/energy monitoring, electrical measurements (V/A/Hz/PF/THD), energy mode control.
cip-file 0x37 File Object — firmware upload/download with fragmented transfer, file directory listing, metadata access.
cip-param 0x0F Parameter Object — device parameterization, discovery scan, read/write with scaling support.

Tag Addressing

CIP Symbolic (Logix)
Format Example Description
Simple MyTag Read/write a tag
Bit access MyDint.5 Read/write bit 5 of a DINT
Array element MyArray[3] Single array element
Array range MyArray[0..9] Read elements 0-9 via fragmented read
Program-scoped Program:MainProgram.MyTag Tag inside a program
Batch msg.tags = ["Tag1","Tag2"] Multi-tag read via TagGroup
PCCC (SLC/MLX/PLC-5)
Format Example Description
Integer N7:0 Integer file 7, element 0
Float F8:5 Float file 8, element 5
Bit B3:0/5 Bit file 3, element 0, bit 5
Timer T4:0 Full timer (CTL/PRE/ACC)
Timer sub-element T4:0.ACC Timer accumulator only
Counter C5:0.ACC Counter accumulator
Output/Input O:0/3, I:1/0 I/O with bit access
Status S:1/5 Status file with bit
String ST9:0 String file
Long L10:0 Long integer file

Configuration

cip-endpoint
Setting Default Description
IP Address PLC IP address
Port 44818 EtherNet/IP port
Slot 0 Backplane slot (ControlLogix)
Timeout (ms) 5000 Connection timeout
Retry (ms) 5000 Reconnection interval
Micro800 off Enable for Micro800 (skips ForwardOpen, uses UCMM)
Routing Path Multi-hop routing (e.g. 1/0/2/192.168.1.1)
cip-pccc-endpoint
Setting Default Description
IP Address PLC IP address
Port 44818 EtherNet/IP port
Timeout (ms) 5000 Connection/request timeout
Retry (ms) 5000 Reconnection interval
cip-io-scanner
Setting Default Description
Target IP I/O adapter / drive IP address
Port 44818 EtherNet/IP port
RPI (ms) 100 Requested Packet Interval (cyclic rate)
Input/Output Assembly 100 / 150 Assembly instance numbers (see device EDS)
Config Assembly 0 Optional config assembly instance
Input/Output Size 32 Application data size in bytes (excl. Run/Idle header)
UDP Port 2222 Local UDP port for implicit I/O
32-bit Run/Idle header on Prepend the Run/Idle header on O→T. Required by the ODVA AC/DC drive profile — leave on for PowerFlex drives, or they stay idle and ignore the output assembly
Electronic keying off Add an Electronic Key segment to the connection path. Off = no key ("don't check identity"), the most compatible choice. Enable only if a strict target rejects an unkeyed connection, then fill in Vendor ID / Device Type / Product Code / Major+Minor revision (from the device EDS). The compatibility bit accepts compatible revisions instead of an exact match

The produced/consumed assemblies are addressed with Connection Point path segments and the connection is opened with the transport direction set to Server (0x81) — both required by stricter drive firmware such as the PowerFlex 525.

Drive Control (PowerFlex 525)

A PowerFlex 525 is controlled with implicit (Class 1) messaging via cip-io-scanner — not with the tag nodes (it has no Logix tags). The drive's native assembly instances (verified against a working PLC→PF525 capture) are:

Setting Value
Output Assembly / Size 2 / 4 (Logic Command word + Speed Reference word)
Input Assembly / Size 1 / 8 (Logic Status word + Speed Feedback + datalinks)
Config Assembly 6
RPI 100 ms (the PLC requests 0 and the drive negotiates ~98 ms)
32-bit Run/Idle header on
Electronic keying off (enable only if the drive refuses the unkeyed connection)

These native instances (Output 2 / Input 1 / Config 6) differ from the generic ODVA AC-drive assemblies (20/70). Send the 4 output bytes as a Buffer in msg.payload (bytes 0-1 = Logic Command, bytes 2-3 = Speed Reference, little-endian). Toggle the drive between Run and Idle with msg.command:"run"/"idle" (or msg.run:true/false).

Device parameters (read/write) use explicit messaging via cip-param (Parameter Object 0x0F), not cip-write. Confirm the exact assembly numbers, Logic Command bit map, and Speed Reference scaling against PowerFlex publication 520-UM001 — they differ between the ODVA AC-drive assemblies (20/70) and the PowerFlex-native ones.

Features

Connection Management
  • Auto-reconnect with configurable retry interval
  • Connection metrics — response times, error counts, uptime tracking
  • Micro800 mode — bypasses UnconnectedSend, uses direct UCMM messaging
  • Multi-hop routing — reach PLCs behind ControlLogix backplanes
Backpressure Protection

All nodes skip subsequent requests while a previous one is in-flight, preventing PLC overload.

Atomic Bit Operations

Write nodes support CIP Read-Modify-Write service (0x4E) for safe bit manipulation without race conditions.

Admin HTTP Endpoints
  • GET /cip-endpoint/:id/browse — browse tags from a deployed endpoint
  • GET /cip-endpoint/:id/metrics — connection statistics (response times, error counts, uptime)
Status Indicators
Color Shape Meaning
Green dot Connected / OK
Yellow ring Connecting / warning
Red ring Error / disconnected
Blue dot Operation in progress

Docker Simulation Environment

A multi-profile PLC simulator is included for development and testing.

docker compose up -d
Services
Container Description Port
plc-clx ControlLogix simulator 44818
plc-cplx CompactLogix simulator 44819
plc-micro Micro800 simulator 44820
plc-mlx MicroLogix simulator (PCCC) 44821
plc-plc5 PLC-5 simulator (PCCC) 44822
drive-powerflex525 PowerFlex 525 drive — implicit Class 1 I/O 44823 (TCP) + 2222 (UDP)
node-red Node-RED with pre-loaded test flows 11880
Simulator Profiles

Each profile provides a realistic tag set:

  • ControlLogix — 10 tags (BOOL, INT, DINT, REAL, STRING, program-scoped)
  • CompactLogix — Same as CLX
  • Micro800 — 24 I/O tags (10 DO + 14 DI, all BOOL)
  • MicroLogix — PCCC registers (N7, F8, B3, T4, C5, S)
  • PLC-5 — PCCC registers
  • PowerFlex 525 — no tags; implicit Class 1 I/O only (assemblies: Output 2 / Input 1 / Config 6). Models the drive's strict Forward_Open acceptance — the connection is granted only when the produced/consumed assemblies use Connection Point path segments and the transport is Server + Class 1
Simulated CIP Services
Service Code Description
RegisterSession 0x0065 Session establishment
ForwardOpen/Close 0x54/0x4E Connected messaging
ReadTag 0x4C Read tag values
WriteTag 0x4D Write tag values
GetInstanceAttributeList 0x55 Tag browsing
GetAttributeAll 0x01 Controller identity
GetAttributeSingle 0x0E Single attribute read
ExecutePCCC 0x4B PCCC over CIP
MultipleServicePacket 0x0A Batch operations
Implicit I/O (Class 1) Cyclic UDP assemblies for the PowerFlex 525 drive profile (ForwardOpen + UDP 2222)
Quick Start
# Start everything
docker compose up -d

# Open Node-RED
open http://localhost:11880

# View simulator logs
docker compose logs -f plc-clx

# Stop
docker compose down

Example Flows

Pre-built flows are included in examples/:

  • basic-read-write.json — Simple read/write operations
  • full-test-flow.json — 6 tabs covering all simulators and node types

Import via Node-RED: Menu > Import > select file.

Testing

npm test

Tests cover:

  • Tag name parsing (bit, array, range, program-scoped)
  • Bit manipulation (getBit, setBit, buildBitMasks)
  • CIP status/type name resolution
  • PCCC address parsing (all file types, sub-elements, bit access)
  • PCCC command building and response parsing
  • CIP path building (8-bit/16-bit segments, attributeId edge cases)
  • Forward_Open framing — strict PowerFlex 525 acceptance (transport byte, Connection Point vs Instance segments, electronic key parsing)
  • cip-io-scanner end-to-end — the real node drives the PowerFlex 525 simulator over TCP ForwardOpen + cyclic UDP I/O, asserting the connection establishes and data flows both directions

To exercise implicit I/O manually without Docker, run the drive simulator directly and point a cip-io-scanner node (Output 2 / Input 1 / Config 6, sizes 4 / 8, Run/Idle on) at 127.0.0.1:44818:

npm run sim:pf525

API Reference

cip-read Output
{
  "payload": "<tag value>",
  "tagName": "MyDint",
  "dataType": "DINT",
  "timestamp": 1710000000000
}
cip-write Input
{
  "payload": 42,
  "tagName": "MyDint"
}
cip-subscribe Output

Single tag:

{
  "payload": 42,
  "tagName": "MyDint",
  "dataType": "DINT",
  "changed": true,
  "scanRate": 1000,
  "timestamp": 1710000000000
}

Multi-tag:

{
  "payload": { "Tag1": 42, "Tag2": 3.14 },
  "tags": [
    { "name": "Tag1", "value": 42, "type": "DINT", "changed": true },
    { "name": "Tag2", "value": 3.14, "type": "REAL", "changed": false }
  ],
  "scanRate": 1000,
  "timestamp": 1710000000000
}
cip-raw Input
{
  "service": 14,
  "classId": 1,
  "instanceId": 1,
  "attributeId": 1,
  "data": null
}

Multiple Service Packet:

{
  "requests": [
    { "service": 14, "classId": 1, "instanceId": 1, "attributeId": 1 },
    { "service": 14, "classId": 1, "instanceId": 1, "attributeId": 7 }
  ]
}
cip-pccc-read Output
{
  "payload": 1234,
  "address": "N7:0",
  "fileType": "Integer",
  "timestamp": 1710000000000
}

Dependencies

Requirements

  • Node.js >= 16.0.0
  • Node-RED >= 2.0.0

License

MIT